Exadata db節(jié)點網(wǎng)卡異常down處理

IT那活兒 / 1842人閱讀
Exadata db節(jié)點網(wǎng)卡異常down處理
點擊上方“IT那活兒”公眾號,關注后了解更多內(nèi)容,不管IT什么活兒,干就完了?。。?/strong>

背景

日常巡檢發(fā)現(xiàn)db節(jié)點ib1網(wǎng)卡異常down了,查看鏈路狀態(tài)也是down,通過ifconfig ib1 down/up也無法恢復。
  • 環(huán)境
    exadata x8-2
    Image version: 21.2.6
1.1 ib1網(wǎng)卡狀態(tài)沒有running
ib0: flags=4163 mtu 65520
inet 192.168.XX.35 netmask 255.255.252.0 broadcast 192.168.XX.255
inet6 fe80::ba59:9f03:91:7fd1 prefixlen 64 scopeid 0x20
Infiniband hardware address can be incorrect! Please read BUGS section in ifconfig(8).

infiniband 80:00:02:08:FE:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00 txqueuelen 256 (InfiniBand)
RX packets 441801234 bytes 135108307679 (125.8 GiB)
RX errors 0 dropped 0 overruns 0 frame 0
TX packets 571055390 bytes 386080892808 (359.5 GiB)
TX errors 0 dropped 200 overruns 0 carrier 0 collisions 0

ib1: flags=4099 mtu 65520
Infiniband hardware address can be incorrect! Please read BUGS section in ifconfig(8).
infiniband 80:00:02:09:FE:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00 txqueuelen 256 (InfiniBand)

RX packets 44482253 bytes 15202598429 (14.1 GiB)
RX errors 0 dropped 0 overruns 0 frame 0
TX packets 16442693 bytes 4497934510 (4.1 GiB)
TX errors 0 dropped 16 overruns 0 carrier 0 collisions 0

ib0:P02: flags=4163 mtu 65520
inet 192.168.XX.36 netmask 255.255.252.0 broadcast 192.168.XX.255
Infiniband hardware address can be incorrect! Please read BUGS section in ifconfig(8).
infiniband 80:00:02:08:FE:80:00:00:00:00:00:00:00:00:00:00:00:00:00:00 txqueuelen 256 (InfiniBand)

lo: flags=73 mtu 65536
inet 127.0.0.1 netmask 255.0.0.0
inet6 ::1 prefixlen 128 scopeid 0x10
loop txqueuelen 1000 (Local Loopback)
RX packets 64915590345 bytes 15540910225759 (14.1 TiB)
RX errors 0 dropped 0 overruns 0 frame 0
TX packets 64915590345 bytes 15540910225759 (14.1 TiB)
TX errors 0 dropped 0 overruns 0 carrier 0 collisions 0
1.2 鏈路顯示down了
Infiniband device mlx4_0 port 1 status:
default gid: fe80:0000:0000:0000:b859:9f03:0091:7fd1
base lid: 0x2b
sm lid: 0x13
state: 4: ACTIVE
phys state: 5: LinkUp
rate: 40 Gb/sec (4X QDR)
link_layer: InfiniBand

Infiniband device mlx4_0 port 2 status:
default gid: fe80:0000:0000:0000:b859:9f03:0091:7fd2
base lid: 0x2c
sm lid: 0x13
state: 1: DOWN
phys state: 2: Polling
rate: 10 Gb/sec (4X)
link_layer: InfiniBand
1.3 db節(jié)點alert日志顯示IB交換機端口異常
359_1 2022-02-05T22:28:34+08:00 critical "InfiniBand port 
HCA-1:2 is in an invalid state. State : Down Physical Link 
State : Polling Data Rate : 10 Gps Symbol Errors : 0 Received Errors : 0"

到這里可以排除網(wǎng)卡損壞,開始核查所有ib交換機狀態(tài)。


分析原因

在所有ib交換機上執(zhí)行檢查,發(fā)現(xiàn)iba01存在異常。
Environment test started:
Starting Environment Daemon test:
Environment daemon running
Environment Daemon test returned OK
Starting Voltage test:
Voltage ECB OK
Measured 3.3V Main = 3.25 V
Measured 3.3V Standby = 3.37 V
Measured 12V = 11.97 V
Measured 5V = 4.99 V
Measured VBAT = 3.03 V
Measured 2.5V = 2.48 V
Measured 1.8V = 1.78 V
Measured I4 1.2V = 1.21 V
Voltage test returned OK
Starting PSU test:
PSU 0 present OK
PSU 1 present OK
PSU test returned OK
Starting Temperature test:
Back temperature 29
Front temperature 31
SP temperature 46
Switch temperature 57, maxtemperature 60
Temperature test returned OK
Starting FAN test:
Fan 0 not present
Fan 1 running at rpm 15478
Fan 2 running at rpm 15696
Fan 3 running at rpm 15696
Fan 4 not present
FAN test returned OK
Starting Connector test:
Connector test returned OK
Starting Onboard ibdevice test:
Switch OK
All Internal ibdevices OK
Onboard ibdevice test returned OK
Starting SSD test:
SSD test returned OK
Starting Auto-link-disable test:
WARNING Autodisabled ports
Auto-link-disable test returned 1 faults
Environment test FAILED
# listlinkup
Connector 0A Present <-> Switch Port 20 is up (Enabled)
Connector 1A Present <-> Switch Port 22 is down (AutomaticHighErrorRate)
Connector 2A Present <-> Switch Port 24 is down (Enabled)
Connector 3A Present <-> Switch Port 26 is up (Enabled)
Connector 4A Present <-> Switch Port 28 is up (Enabled)
Connector 5A Present <-> Switch Port 30 is up (Enabled)
# showunhealthy
WARNING Autodisabled ports
FAILURE - 1 sensors NOT OK
vendid=0x2c9
devid=0x1003
sysimgguid=0xb8599f0300917fd3
caguid=0xb8599f0300917fd0
Ca 2 "H-b8599f0300917fd0" # "exdadbadm10 S 192.168.XX.35,192.168.XX.36 HCA-1"
[1](b8599f0300917fd1) "S-0010e0cdd353a0a0"[22] # lid 43 lmc 0 "SUN DCS 36P QDR exdasw-ibb01 168.168.XX.37" lid 26 4xQDR

可以確認,連接ib1的連接端口22有報錯,而22端口由于high error rate導致處于關閉狀態(tài)。


處理步驟

3.1 首先清理報錯信息
[root@exdasw-iba01 ~]# ibclearerrors

## Summary: 35 nodes cleared 0 errors
[root@exdasw-iba01 ~]#
[root@exdasw-iba01 ~]#
[root@exdasw-iba01 ~]# ibclearcounters

## Summary: 35 nodes cleared 0 errors
3.2 啟用IB交換機端口并驗證
[root@exdasw-iba01 ~]# enableswitchport --automatic 22

[root@exdasw-iba01 ~]# listlinkup
Connector 0A Present <-> Switch Port 20 is up (Enabled)
Connector 1A Present <-> Switch Port 22 is up (Enabled)

Starting Onboard ibdevice test:
Switch OK
All Internal ibdevices OK
Onboard ibdevice test returned OK
Starting SSD test:
SSD test returned OK
Starting Auto-link-disable test:
Auto-link-disable test returned OK
可以看到狀態(tài)已經(jīng)恢復正常。
再次檢查db節(jié)點ib01網(wǎng)卡,無需人工處理,該網(wǎng)卡已經(jīng)處于running狀態(tài)。
3.3 開始清理告警日志
[root@exdasw-iba01 ~]# spsh

Oracle(R) Integrated Lights Out Manager

Version 2.2.16-3 ILOM 3.2.11 r137127

Copyright (c) 2020, Oracle and/or its affiliates. All rights reserved.

Warning: HTTPS certificate is set to factory default.

Hostname: exdasw-iba01

-> show faulty
Target | Property | Value
----------------------------------+----------------------------------------+-----------------------------------------------------------
/SP/faultmgmt/0                   | fru | /SYS
/SP/faultmgmt/0/faults/0          | class | fault.device.ib.auto-link-disable
/SP/faultmgmt/0/faults/0          | sunw-msg-id | ---
/SP/faultmgmt/0/faults/0          | component | /SYS
/SP/faultmgmt/0/faults/0          | uuid | 8f0fd5cf-661b-e0f5-db37-cfbcbd7b673a
/SP/faultmgmt/0/faults/0          | timestamp | 2022-02-02/10:18:11


-> start /SP/faultmgmt/shell
Are you sure you want to start /SP/faultmgmt/shell (y/n)? y

faultmgmtsp> fmadm faulty
------------------- ------------------------------------ -------------- --------
Time UUID msgid Severity
------------------- ------------------------------------ -------------- --------
2022-02-05/22:22:57 57471550-2815-eba0-ef6b-f46fa7788bad IBSWITCH-8000-D6 Major

Fault class : fault.chassis.device.ib.link-error

FRU : /SYS
(Part Number: 7305544)
(Serial Number: AK00417399)

Description : One or more ports have been auto-disabled due to high error
rate or bad link speed or width.

Response : Illuminate service-required LED on the chassis.

Impact : One or more ports have been auto-disabled due to high error
rate or bad link speed or width.

Action : Please refer to the associated reference document at %s for
the latest service procedures and policies regarding this
diagnosis.

faultmgmtsp> fmadm repair 57471550-2815-eba0-ef6b-f46fa7788bad
faultmgmtsp> fmadm faulty
No problems found
faultmgmtsp> show faulty
Invalid command show - type help for a list of commands.

faultmgmtsp> exit
-> show faulty
Target | Property | Value
------------------------------------------------+--------------------------------------------------------+---------------------------------------------------------------------------------

->
總 結
當網(wǎng)卡出現(xiàn)異常時,不一定是硬件損壞,需要核查整個鏈路上的組件運行狀態(tài)。


本文作者湯 杰(上海新炬中北團隊)

本文來源:“IT那活兒”公眾號

文章版權歸作者所有,未經(jīng)允許請勿轉載,若此文章存在違規(guī)行為,您可以聯(lián)系管理員刪除。

轉載請注明本文地址:http://systransis.cn/yun/129136.html

相關文章

  • 【獨家】終生受用的Redis高可用技術解決方案大全

    摘要:哨兵是社區(qū)版本推出的原生高可用解決方案,部署架構主要包括兩部分集群和數(shù)據(jù)集群,其中集群是由若干節(jié)點組成的分布式集群。自研推薦推薦自研的高可用解決方案,主要體現(xiàn)在配置中心故障探測和的處理機制上,通常需要根據(jù)企業(yè)業(yè)務的實際線上環(huán)境來定制化。 最近很多朋友向我咨詢關于高可用的方案的優(yōu)缺點以及如何選擇合適的方案線上使用,剛好最近在給宜人貸,光大銀行做企業(yè)內(nèi)訓的時候也詳細講過,這里我再整理發(fā)出來...

    cc17 評論0 收藏0
  • 【獨家】終生受用的Redis高可用技術解決方案大全

    摘要:哨兵是社區(qū)版本推出的原生高可用解決方案,部署架構主要包括兩部分集群和數(shù)據(jù)集群,其中集群是由若干節(jié)點組成的分布式集群。自研推薦推薦自研的高可用解決方案,主要體現(xiàn)在配置中心故障探測和的處理機制上,通常需要根據(jù)企業(yè)業(yè)務的實際線上環(huán)境來定制化。 最近很多朋友向我咨詢關于高可用的方案的優(yōu)缺點以及如何選擇合適的方案線上使用,剛好最近在給宜人貸,光大銀行做企業(yè)內(nèi)訓的時候也詳細講過,這里我再整理發(fā)出來...

    helloworldcoding 評論0 收藏0
  • 留給傳統(tǒng) DBA 的時間不多了?看餓了么如何構建數(shù)據(jù)庫平臺自動化

    摘要:因為傳統(tǒng)的數(shù)據(jù)庫管理方式在當前這種架構下依靠手工或者借助簡單的工具是無法應對多活架構大規(guī)模管理帶來的復雜性,因此平臺化顯得非常重。我們在做的方案時做了充分調查及論證,最終沒有選擇這種方式。 蔡鵬,2015年加入餓了么,見證了餓了么業(yè)務&技術從0到1的發(fā)展過程,并全程參與了數(shù)據(jù)庫及DBA團隊高速發(fā)展全過程。同時也完成個人職能的轉型-由運維DBA到DEV-DBA的轉變,也從DB的維穩(wěn)轉變到專心為...

    explorer_ddf 評論0 收藏0

發(fā)表評論

0條評論

IT那活兒

|高級講師

TA的文章

閱讀更多
最新活動
閱讀需要支付1元查看
<